AC2-B0-34-615-3B1-C [Carling Technologies]
CIRCUIT BRKR 15A PANEL MT ROCKER;型号: | AC2-B0-34-615-3B1-C |
厂家: | Carling Technologies |
描述: | CIRCUIT BRKR 15A PANEL MT ROCKER 电路保护 |
文件: | 总23页 (文件大小:3624K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A-Series – General Specifications
Compact size and well known for its proven reliability, the A-Series
utilizes the hydraulic magnetic principle which provides precise
operation and performance even when exposed to extremely hot
and/or cold application environments. When aesthetics demand a
clean contemporary and functional design, the visi-rocker two-color
actuator can be specified. A rockerguard and push-to-reset bezel
help prevent inadvertent actuation. A specially constructed version
is now available for applications requiring CE markings. The
A-Series is used in many telecommunications and marine applica-
tions. In addition, these breakers meet CSA Standard 22.2 No.
100 for the Generator & Welder markets.
1-6 poles (handle), 1-3 poles (rocker). 0.02 - 50 amps, up to 277
VAC or 80 VDC, with a choice of time delays, terminals and actua-
tor colors.
Agency Certifications
UL Recognized
UL Listed
UL Standard 1077
Component Recognition Program
as Protectors Supplementary
UL Standard 489A
Communications Equipment (Guide
CCN/DITT, File E189195)
(Guide CCN/QVNU2, File E75596)
CSA Accepted
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000 CSA
UL Standard 508
UL Standard 1500
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
Standard C22.2 No. 235
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
TUV Certified
VDE Certified
EN60934, under License No.
R72040875
EN60934, VDE 0642 under File No.
10537
34
www.carlingtech.com
A-Series – General Specifications
Electrical
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector.
Notes for Table A:
1
2
3
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
Same as note 1, except that backup fuse is limited to 80 A maximum.
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC,
1Ø Power System.
4
Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators.
www.carlingtech.com
35
A-Series – General Specifications
Electrical
Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component
Supplementary Protector.
Notes for Table B:
1
2
3
4
General Purpose Ratings for UL/CSA Only.
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
Same as note 2, except that backup fuse is limited to 80 A maximum.
Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators.
Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
A-SERIES TABLE C: UL1500 (Marine Ignition Protected)
SHORT CIRCUIT
CAPACITY
(AMPS)
CURRENT
RATING
VOLTAGE
APPLICATION CODES
CIRCUIT
CONFIGURATION
MAX.
RATING
FULL LOAD
AMPS
WITHOUT
BACKUP FUSE
FREQUENCY
PHASE
UL
CSA
1
SERIES
14
DC
DC
---
---
---
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 30
5000
5000
3000
1500
1000
TC1,2,OL1,U1 TC1,2,OL1,U1
TC1,2,OL1,U2 TC1,2,OL1,U2
TC1,2,OL1,U1 TC1,2,OL1,U1
TC1,2,OL1,U1 TC1,2,OL1,U1
TC1,2,OL1,U1 TC1,2,OL1,U1
32 1
65
DC
2
125 / 250
250
50 / 60
50 / 60
1
1
Notes for Table C:
1
2
Available with special catalog number only (consult factory).
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.
Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A.
Notes for Table C:
1
Parallel Pole Construction
36
www.carlingtech.com
A-Series – General Specifications
Electrical
Mechanical
Maximum Voltage
Current Ratings
277VAC 50/60 Hz, 80VDC
Endurance
Trip Free
10,000 ON-OFF operations @ 6 per
minute; with rated Current & Voltage.
All A-Series Circuit Breakers will trip
on overload, even when the actuator
is forcibly held in the ON position.
The operating actuator moves posi-
tively to the OFF position when an
overload causes the circuit breaker
to trip. When mid-trip handle is spec-
ified, the handle moves to the mid
position on electrical trip of the cir-
cuit breaker. When mid-trip handle
with alarm switch is specified, the
handle moves to the mid position &
the alarm switch actuates when the
circuit breaker is electrically tripped.
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0, 50.0. Other ratings available -
consult ordering scheme.
DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
SPDT; 10.1 A - 250VAC,
Trip Indication
Standard Voltage Coils
Auxiliary Switch Rating
1.0 A-65VDC/0.5 A - 80 VDC,
0.1A - 125VAC (with gold contacts).
Minimum: 100 Megohms at 500 VDC
UL, CSA - 1500V 60 Hz for one
minute between all electrically isolat-
ed terminals. A-Series rocker circuit
breakers comply with the 8mm spac-
ing & 3750V dielectric requirements
from hazardous voltage to operator
accessible surfaces per EN 60950
and VDE 0805.
Insulation Resistance
Dielectric Strength
Physical
Number of Poles
1 - 6 Poles (handle) and 1-3 poles
(rocker) at 30 Amps or less. 1 and 2
poles at 31 Amps thru 50 Amps.
Resistance, Impedance
Values from Line to Load Terminal -
based on Series Trip Circuit Breaker.
Internal Circuit Configurations Series, (with or without auxiliary
switch), Shunt and Relay with cur-
rent or voltage trip coils, Dual Coil,
Switch Only with or without auxiliary
switch.
Weight
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Housing - Black; Actuator- See
Ordering Scheme.
Standard Colors
Environmental
Designed and tested in accordance with requirements of specifi-
cation MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C, Test
Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Pulse Tolerance Curves
Vibration
Moisture Resistance
Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH.56
days @ +85°C, 85% RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Thermal Shock
Operating Temperature
-40° C to +85° C
www.carlingtech.com
37
A-Series Handle UL Recognized – Ordering Scheme
10 450
–
–
–
–
–
A
3
1
B 1
A
B
0
C
8
5
11
Agency
Approval
1
3
7
9
10
2
4
6
Mounting/
Terminal
Aux/Alarm
Switch
Series
Poles
Current Rating
Actuator
Color
Actuator
Circuit
Frequency
& Delay
Barriers
1 SERIES
7 CURRENT RATING (AMPERES)
A
020
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
611
711
11.000
11.500
025
030
035
040
045
050
055
060
065
070
075
080
085
090
095
210
215
220
2 ACTUATOR1
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
6358 35.000
6408 40.000
6458 45.000
6508 50.000
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
4 CIRCUIT
A2
B
C
D3
E3
F3
G3
Relay Trip (Current)
Relay Trip (Voltage)
Switch Only (No Coil)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
H3,4 Dual Coil with Shunt Trip
Voltage Coil
K3,4 Dual Coil with Relay Trip
Voltage Coil
610 10.000
710 10.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
5 AUXILIARY/ALARM SWITCH 5
5
S.P.S.T., 0.093 Q.C.
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65
K20 120 AC
L40 240 AC
65 AC
0
1
2
3
4
w/o Aux Switch
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
A12 12 DC
A18 18 DC
A24 24 DC
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
7
J06
6 AC
8
9
8 TERMINAL9
E11
F
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
110
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
6 FREQUENCY & DELAY
311
4
G
03
DC 50/60Hz, Switch Only
30
31
32
34
36
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
106 DC Instantaneous
511
6
H11 Screw M5 (Bus Type)
11
12
14
16
DC Ultra Short
DC Short
L12
0.250 Q.C./ Solder Lug
M11 M6 Threaded Stud
DC Medium
DC Long
7
8
9
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
Screw 10-32 (Bus Type) and
30° bend
Q14 Push-In Stud
427 50/60Hz Short, Hi-Inrush
447 50/60Hz Medium, Hi-Inrush
467 50/60Hz Long, Hi-Inrush
527 DC, Short,Hi-Inrush
R
Screw M4 w/upturned lugs
and 30° bend
Screw M4 (Bus Type)
and 30° bend
Printed Circuit Board
Terminals
Push-On 0.110 Tab (Q.C.)
206 50/60Hz Instantaneous
21
22
24
26
50/60Hz Ultra Short
50/60Hz Short0
50/60Hz Medium
50/60Hz Long
T11
P13
S13
547 DC,Medium, Hi-Inrush
567 DC, Long, Hi-Inrush
B
C
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Notes:
1
Actuator Code:
9 ACTUATOR COLOR & LEGEND
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
Actuator Color
White
Black
Red
Green
Blue
Yellow
Gray
I-O
A
C
F
H
K
M
P
ON-OFF Dual
Legend Color
Black
2 pole - left pole
3 pole - center pole
B
D
G
J
1
2
3
4
5
6
7
8
9
4 pole - two handles at center poles 5 pole - three handles at center poles
6 pole - four handles at center poles
White
White
White
White
Black
Black
Black
White
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with cir-
cuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
L
N
Q
S
U
2
Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps,
select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with
standard half shells. 35-50A - supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
Orange
R
T
Black (short handle)15
3
4
10 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
5
Threaded Inserts, 2 per pole
6-32 x 0.195 inches
1
no
yes
no
6
A
2
6-32 X 0.195 inches
ISO M3 x 5mm
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSA Accepted available in one and two pole breakers.
B
ISO M3 x 5mm (multipole only)
yes
Front panel Snap-In, 0.75” wide bezel
without Handleguard
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96" wide;
8
5
6
no
yes
9
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q..
Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Certification up to 30 amps, but not recommended over 20 amps.
Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted avail-
able up to 30A.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with
Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board)
are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A,
B and C.
10
11
7
8
no
multipole units have .105" bezel overhang on all sides
without Handleguard, 1-pole 0.96" wide;
yes
(multipole only) .105" bezel overhang on all sides
12
13
11 AGENCY APPROVAL
C
D
E
I
UL Recognized & CSAAccepted
VDE Certified, UL Recognized & CSAAccepted
TUV Certified, UL Recognized & CSAAccepted
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSAAccepted
14
15
Terminal Code Q not available with VDE certification.
Single pole only.
38
www.carlingtech.com
A-Series Handle UL489A – Ordering Scheme
14 450
A
–
–
– T
M
1
1
B 1
A
B – –
0
12
11
8
5
1
3
7
9
10
2
4
6
Mounting/
Agency
Terminal
Aux/Alarm
Switch
Max. Appl.
Series
Poles
Current Rating
Actuator
Color
Actuator
Circuit
Frequency
& Delay
Barriers
Approval
Rating
8 TERMINAL5
1 SERIES
A
16
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
37
4
57
6
B
F
Screw M5 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
2 ACTUATOR1
A
S
T
Handle, one per pole
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
G
H
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
7
8
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
3 POLES2
One
M7 M6 Threaded Stud
1
2
Two
3
7
Three
4 Four
P8
Printed Circuit Board
Terminals
Push-In Stud
Q9
4 CIRCUIT
Series Trip (Current)
B
9 ACTUATOR COLOR
LEGEND
ON-OFF Dual
White
Black
Red
Green
Blue
Yellow
5 AUXILIARY/ALARM SWITCH2
Legend Color
0
1
2
3
w/o Aux Switch
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
B
D
G
J
1
2
3
4
5
6
7
8
9
Black
White
White
White
White
Black
Black
Black
White
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
8
9
L
6 FREQUENCY & DELAY
N
Q
S
U
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
523 DC, Short,Hi-Inrush
543 DC, Medium, Hi-Inrush
563 DC, Long, Hi-Inrush
Gray
Orange
Black (short handle)10
10 MOUNTING/BARRIERS
7 CURRENT RATING (AMPERES)
MOUNTING STYLE
BARRIERS
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
415
517
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6354
6404
6454
6504
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
Threaded Insert, 2 per pole
6-32 x 0.195 inches
6-32 X 0.195 inches
ISO M3 x 5mm
ISO M3 x 5mm (multipole only)
1
A
2
no
yes
no
B
yes
Front panel Snap-In, 0.75” wide bezel
without Handleguard
5
6
no
yes
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96" wide;
multipole units have .105" bezel overhang on all sides
without Handleguard, 1-pole 0.96" wide;
(multipole only) .105" bezel overhang on all sides
7
8
no
yes
11 MAXIMUM APPLICATION RATING
80 DC
M
12 AGENCY APPROVAL
T
K
J
UL489A LISTED
UL489A LISTED, VDE CERTIFIED
UL489A LISTED, TUV CERTIFIED
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker.
2
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right
pole.
3
4
VDE Certified to 30 amps. UL489A Listed to 50 amps.
VDE Certification available with single pole breakers only. UL489A Listing available with
one and two pole breakers.
5
6
7
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9 G, H, M and Q.
Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps
with UL489A Listing, but is not recommended over 20 amps.
Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
Terminal Code Q not available with VDE certification.
8
9
10
Single pole only.
www.carlingtech.com
39
A-Series Handle WORLD – Ordering Scheme
14 450
–
–
A
– –
–
3
1
A 1
A
B
0
P
8
5
11
Agency
Approval
1
3
7
9
10
2
4
6
Mounting/
Terminal
Aux/Alarm
Switch
Series
Poles
Current Rating
Actuator
Color
Actuator
Circuit
Frequency
& Delay
Barriers
1 SERIES
A
7 CURRENT RATING (AMPERES)
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
285
290
295
410
512
415
517
420
522
527
430
435
440
445
450
0.850
0.900
0.950
1.000
1.250
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
455
460
465
470
475
480
485
490
495
610 10.000
710 10.500
611
711
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
6358 35.000
6408 40.000
6458 45.000
6508 50.000
2 ACTUATOR1
A
S
T
Handle, one per pole
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
11.000
11.500
4 CIRCUIT
D3
E3
Shunt Trip (Current)
Shunt Trip (Voltage)
A2
B
C
Switch Only (No Coil)
Series Trip (Current)
Series Trip (Voltage)
612 12.000
712 12.500
H3,4 Dual Coil with Shunt Trip
Voltage Coil
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65
K20 120 AC
L40 240 AC
65 AC
5 AUXILIARY/ALARM SWITCH 5
A12 12 DC
A18 18 DC
A24 24 DC
0
2
3
w/o Aux Switch
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
J06
6 AC
8 TERMINAL9
B
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
6 FREQUENCY & DELAY
110
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
C
03
DC 50/60Hz, Switch Only
30
31
32
34
36
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
E11
F
106 DC Instantaneous
311
4
11
12
14
16
DC Ultra Short
DC Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
511
6
G
Screw M5 (Bus Type)
and 30° bend
DC Medium
DC Long
427 50/60Hz Short, Hi-Inrush
447 50/60Hz Medium, Hi-Inrush
467 50/60Hz Long, Hi-Inrush
527 DC, Short,Hi-Inrush
H11 Screw M5 (Bus Type)
R
206 50/60Hz Instantaneous
7
8
9
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
Screw 10-32 (Bus Type) and
30° bend
Screw M4 w/upturned lugs
and 30° bend
Screw M4 (Bus Type)
and 30° bend
21
22
24
26
50/60Hz Ultra Short
50/60Hz Short0
50/60Hz Medium
50/60Hz Long
T11
547 DC,Medium, Hi-Inrush
567 DC, Long, Hi-Inrush
9 ACTUATOR COLOR & LEGEND
Actuator Color
White
Black
Red
Green
Blue
Yellow
Gray
Orange
I-O
A
C
F
H
K
M
P
Dual
1
2
3
4
5
6
7
8
Legend Color
Black
White
White
White
White
Black
Black
Black
R
10 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Inserts, 2 per pole
6-32 x 0.195 inches
1
no
A
2
6-32 X 0.195 inches
ISO M3 x 5mm
yes
no
B
ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
without Handleguard
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96" wide;
multipole units have .105" bezel overhang on all sides
without Handleguard, 1-pole 0.96" wide;
(multipole only) .105" bezel overhang on all sides
yes
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with
circuit codes B, C, D, E, and H.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of
the breaker. Available with circuit codes B & C.
Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code
630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10, 20 & 30.
5
6
no
yes
7
8
no
2
yes
3
4
11 AGENCY APPROVAL
P
Q
TUV Certified, UL Recognized & CSAAccepted
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSAAccepted
5
6
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized,
CSA Accepted & TUV Certified to 50 amps.
8
9
Available up to two poles with AC or DC delays.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G and H.
10
11
Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps.
Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers.
These breakers are ONLY TUV Certified when the washers are used.
40
www.carlingtech.com
A-Series Sealed Toggle UL Recognized – Ordering Scheme
–
10 450
– –
Current Rating
–
–
A
1
1
0 1
M
B
0
C
8
5
1
3
7
9
10
2
4
6
11
Mounting/
Terminal
Agency
Aux/Alarm
Switch
Series
Poles
Legend
Plate
Actuator
Circuit
Frequency
& Delay
Barriers
Approval
1 SERIES
7 CURRENT RATING (AMPERES)
A
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
095
210
215
220
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
2.000
611
711
11.000
11.500
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
6358 35.000
6408 40.000
6458 45.000
6508 50.000
2 ACTUATOR1
Sealed Toggle, one per unit
M
3 POLES
1
2
3
One
Two
Three
4 CIRCUIT
A2
B
C
D3
E3
F3
G3
Relay Trip (Current)
Relay Trip (Voltage)
Switch Only (No Coil)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
H3,4 Dual Coil with Shunt Trip
Voltage Coil
K3,4 Dual Coil with Relay Trip
Voltage Coil
610 10.000
710 10.500
5 AUXILIARY/ALARM SWITCH 5
5
S.P.S.T., 0.093 Q.C.
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
A06
A12 12 DC
A18 18 DC
A24 24 DC
0
1
2
3
4
w/o Aux Switch
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65
K20 120 AC
L40 240 AC
65 AC
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
7
J06
6 AC
8
9
8 TERMINAL9
E
F
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
110
2
3
4
5
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
6 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
30
31
32
34
36
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
G
106 DC Instantaneous
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
H
6
L11
M
Q
R
427 50/60Hz Short, Hi-Inrush
447 50/60Hz Medium, Hi-Inrush
467 50/60Hz Long, Hi-Inrush
527 DC, Short,Hi-Inrush
7
8
9
206 50/60Hz Instantaneous
21
22
24
26
50/60Hz Ultra Short
50/60Hz Short0
50/60Hz Medium
50/60Hz Long
T
Screw M4 (Bus Type)
and 30° bend
Printed Circuit Board
Terminals
547 DC,Medium, Hi-Inrush
567 DC, Long, Hi-Inrush
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
P12
S12
B
C
Push-On 0.110 Tab (Q.C.)
Notes:
1
Actuator Code M: Handle location as viewed from front of panel:
2 pole - right pole 3 pole - center pole
9 LEGEND PLATE
0
No legend plate
2
Switch Only circuits, rated up to 50 amps and 3 poles. For .02 to 30 amps, select
Current Code 630. For 35 - 50 amps, select Current Code 650.
3
4
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps.
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right
pole.
Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized,
CSA Accepted & TUV Certified to 50 amps.
10 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
no
yes
1
Standard Hex Nut
5
A
Standard Hex Nut (multipole only)
11 AGENCY APPROVAL
UL Recognized & CSAAccepted
6
7
C
8
9
UL Recognition and CSA Certification available on one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q..
Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recom-
mended over 20 amps.
10
11
12
Terminal Code L : available up to 30A.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50
amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed
Circuit Board) are available up to 40 amps with Circuit Codes A, B and C.
www.carlingtech.com
41
A-Series Rocker UL Recognized – Ordering Scheme
630
–
24
A
–
–
3 1
D
Mounting/
Agency
1
2
F
–
–
B
0
8
11
1
3
7
9
10
2
5
4
6
Terminal
Series
Poles
Current Rating
Actuator
Color
Actuator
Aux/Alarm
Switch
Circuit
Frequency
& Delay
Barriers
Approval
1 SERIES
A
7 CURRENT RATING (AMPERES)
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
095
210
215
220
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
420
2.000
611
711
11.000
11.500
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
2 ACTUATOR 1
Two Color Visi-Rocker
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
63510 35.000
64010 40.000
64510 45.000
65010 50.000
Push-To-Reset , Single color
C
D
E
F
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate ON, no legend
R
U
V
Vertical legend
Horizontal legend
No legend
Indicate OFF, vertical legend
G
H
Indicate OFF, horizontal legend
Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N
O
P
Indicate OFF,
vertical legend
Indicate OFF,
horizontal legend
Indicate OFF,
no legend
610 10.000
710 10.500
Single color
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)
A06
A12 12 DC
A18 18 DC
A24 24 DC
J
Vertical legend
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65
K20 120 AC
L40 240 AC
65 AC
K
L
Horizontal legend
No legend
J06
6 AC
3 POLES2
8 TERMINAL11
E13
F
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
1
One
2
Two
3
Three
112
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
4 CIRCUIT
F4
Relay Trip (Current)
Relay Trip (Voltage)
313
4
G
A3
B
C
D4
E4
Switch Only (No Coil)
G4
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
H4, 5 Dual Coil with Shunt Trip
Voltage Coil
513
6
H13 Screw M5 (Bus Type)
L14
M13 M6 Threaded Studs
0.250 Q.C./ Solder Lug
K4, 5 Dual Coil with Relay Trip
Voltage Coil
7
8
9
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
Screw 10-32 (Bus Type) and
30° bend
P15
Printed Circuit Board
Terminals
5 AUXILIARY/ALARM SWITCH6, 7
5
S.P.S.T., 0.093 Q.C.
Q16 Push-In Stud
R
0
1
2
3
4
w/o Aux Switch
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
Screw M4 w/upturned lugs
and 30° bend
Push-On 0.110 Tab (Q.C.)
Screw M4 (Bus Type)
and 30° bend
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
7
S17
T
B
C
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
8
9
9 ACTUATOR COLOR & LEGEND
Actuator or _______Marking: _______
Visi-Color 12 I-O ON-OFF Dual12
6 FREQUENCY & DELAY
____Marking Color:
Single Color Visi-Rocker
03
DC 50/60Hz, Switch Only
30
31
32
34
36
42
44
46
52
54
56
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
108 DC Instantaneous
White
Black
Red
Green
Blue
Yellow
Gray
Orange
A
C
F
H
K
M
P
R
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Green
Blue
Yellow
Gray
Orange
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
9
9
9
9
9
L
208 50/60Hz Instantaneous
N
Q
S
21
22
24
26
50/60Hz Ultra Short
50/60Hz Short
50/60Hz Medium
50/60Hz Long
10 MOUNTING/BARRIERS20
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
BARRIERS
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker
per breaker.
1
6-32 x 0.195 inches
no
yes
no
A
2
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
3
Switch Only circuits, rated up to 50 amps & 3 poles, are available with VDE Certification when tied to a protected pole (Circuit
Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip
instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are
supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSAAccepted & TUV Certified to 50
amps.
Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA
Accepted available in one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal
Codes 5, 9, G, H, M and Q.
Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSAAccepted up to 30 amps, but not recom-
mended over 20 amps.
Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud)
with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used.
VDE Cert. available up to 12 amps. UL Rec. & CSAAccepted available up to 30 amps.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50
amps with UL Recognition and CSAAccepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P
(Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C.
Terminal Code Q not available with VDE.
Terminal Code S used on voltage coil circuit constructions only.
Color shown is visi and legend with remainder of rocker black.
Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset
bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L.
4
5
B
ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
6
3
6-32 x 0.195 inches
no
yes
no
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
7
8
9
D
ISO M3 x 5mm (multi-pole units only)
FRONT PANEL SNAP-IN BRACKET, 0.744” wide bezel
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
FRONT PANEL SNAP-IN BRACKET, 0.96” wide bezel
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
yes
10
11
12
13
8
H
no
no
9
J
no
no
14
15
11 AGENCY APPROVAL
C
D
E
I
UL Recognized & CSAAccepted
VDE Certified, UL Recognized & CSAAccepted
TUV Certified, UL Recognized & CSAAccepted
16
17
18
19
20
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSAAccepted
42
www.carlingtech.com
A-Series Rocker UL489A – Ordering Scheme
14 450
–
–
–
–
–
A
T
1
1
3 1
F
B
0
M
12
Agency
Approval
8
5
11
1
3
7
9
10
2
4
6
Mounting/
Terminal
Aux/Alarm
Switch
Max. Appl.
Rating
Series
Poles
Current Rating
Actuator
Color
Actuator
Circuit
Frequency
& Delay
Barriers
8 TERMINAL5
9
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board
Terminals
1 SERIES
A
16
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
B
F
37
4
57
6
2 ACTUATOR 1
Two Color Visi-Rocker
Push-To-Reset, Visi-Rocker
G
C
D
F
Indicate ON, vertical legend
N
Indicate OFF,
vertical legend
Indicate OFF,
Indicate ON, horizontal legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
H
M7
P8
O
G
horizontal legend
7
8
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
Push-To-Reset , Single color
Single color
Q9
Push-In Stud
R
U
Vertical legend
Horizontal legend
J
K
Vertical legend
Horizontal legend
9 ACTUATOR COLOR & LEGEND
Actuator or
10
Visi-Color
Marking
Marking Color:
10
ON-OFF
Dual
Single Color
Visi-Rocker
White
n/a
White
Black
Red
Green
Blue
Yellow
Gray
Orange
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
Red
Green
Blue
L
N
Q
S
Yellow
Gray
3 POLES2
One
Orange
1
2
Two
3 Three
10 MOUNTING/BARRIERS 11
4 CIRCUIT
Series Trip (Current)
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
BARRIERS
B
1
no
yes
no
5 AUXILIARY/ALARM SWITCH3
A
2
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
0
1
2
3
w/o Aux Switch
7
S.P.S.T., 0.110 Q.C.
B
ISO M3 x 5mm (multi-pole units only)
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
yes
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
8
9
3
no
C
4
D
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
yes
no
yes
6 FREQUENCY & DELAY
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
52
54
56
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
8
H
no
no
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
9
J
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
no
no
7 CURRENT RATING (AMPERES)
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
415
517
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6355
6405
6455
6505
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
11 MAXIMUM APPLICATION RATING
80 DC
M
12 AGENCY APPROVAL
T
K
J
UL489A Listed
UL489A Listed, VDE Certified
UL489A Listed, TUV Certified
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or
mixed poles, and have one rocker per breaker.
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half
shells. 30-50A are supplied with extended boat (B-Style) half shells.
VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, M and Q.
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only TUV or VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL489A Listing.
3
4
5
6
7
8
9
Terminal Code Q not available with VDE certification.
10
11
Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N
& O. Rockerguard available with actuator codes C through K.
www.carlingtech.com
43
A-Series Flat Rocker UL Recognized – Ordering Scheme
24 630
–
–
–
–
3 1
E
Mounting/
Agency
–
A
1
2
1
B
0
8
5
11
1
3
7
9
10
2
4
6
Terminal
Aux/Alarm
Switch
Series
Poles
Current Rating
Actuator
Color
Actuator
Circuit
Frequency
& Delay
Barriers
Approval
1 SERIES
A
7 CURRENT RATING (AMPERES)
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
095
210
215
220
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
611
711
11.000
11.500
2 ACTUATOR 1
Two Color Visi-Rocker
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
63510 35.000
64010 40.000
64510 45.000
65010 50.000
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Single color
3
4
Vertical legend
Horizontal legend
Push-To-Reset, Visi-Rocker
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Push-To-Reset , Single color
7
8
Vertical legend
Horizontal legend
610 10.000
710 10.500
3 POLES2
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)
A06
A12 12 DC
A18 18 DC
A24 24 DC
1
One
2
Two
3
Three
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65
K20 120 AC
L40 240 AC
65 AC
4 CIRCUIT
F4
Relay Trip (Current)
Relay Trip (Voltage)
A3
B
C
D4
E4
Switch Only (No Coil)
G4
J06
6 AC
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
H4, 5 Dual Coil with Shunt Trip
Voltage Coil
8 TERMINAL11
E13
F
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
112
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
K4, 5 Dual Coil with Relay Trip
Voltage Coil
313
4
G
5 AUXILIARY/ALARM SWITCH6, 7
5
S.P.S.T., 0.093 Q.C.
513
6
H13 Screw M5 (Bus Type)
0
1
2
3
4
w/o Aux Switch
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
L14
0.250 Q.C./ Solder Lug
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
7
M13 M6 Threaded Studs
7
8
9
P15
Printed Circuit Board
Terminals
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Push-On 0.110 Tab (Q.C.)
Screw M4 (Bus Type)
and 30° bend
8
9
Q
R
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
S16
T
6 FREQUENCY & DELAY
B
C
03
DC 50/60Hz, Switch Only
30
31
32
34
36
42
44
46
52
54
56
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
108 DC Instantaneous
11
12
14
16
DC Ultra Short
DC Short
9 ACTUATOR COLOR & LEGEND
Actuator or _______Marking: _______
Visi-Color 17 I-O ON-OFF Dual17
White
Black
Red
Green
Blue
Yellow
Gray
DC Medium
DC Long
____Marking Color:
Single Color Visi-Rocker
9
9
9
9
9
208 50/60Hz Instantaneous
A
C
F
H
K
M
P
R
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Green
Blue
Yellow
Gray
Orange
21
22
24
26
50/60Hz Ultra Short
50/60Hz Short
50/60Hz Medium
50/60Hz Long
L
N
Q
S
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles,
and have one rocker per breaker.
Orange
3
Switch Only circuits, rated up to 50 amps & 3 poles. For .02 to 30 amps, select Current Code 630. For
35 - 50 amps, select Current Code 650.
10 MOUNTING/BARRIERS18
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
BARRIERS
4
5
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction,
Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and
are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half
shells. 30-50A are supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps.
UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only
available with Terminal Codes 5, 9, G, H, M and Q.
Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.
Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M
(M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV
Certified when the washers are used.
1
6-32 x 0.195 inches
no
yes
no
6
A
2
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
7
8
9
10
11
B
ISO M3 x 5mm (multi-pole units only)
RECESSED OFF SIDE ROCKER ACTUATOR 19
6-32 x 0.195 inches
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
6-32 x 0.195 inches
yes
5
E
6
F
no
yes
no
12
13
yes
14
15
TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL
Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with
Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA
Accepted with Circuit Codes A, B and C.
3
no
yes
no
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
16
17
18
Terminal Code S used on voltage coil circuit constructions only.
D
ISO M3 x 5mm (multi-pole units only)
yes
Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on
Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6.
Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink
stamping only.
19
11 AGENCY APPROVAL
C
E
I
UL Recognized & CSAAccepted
TUV Certified, UL Recognized & CSAAccepted
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSAAccepted
44
www.carlingtech.com
A-Series Flat Rocker UL 489A – Ordering Scheme
14 630
–
–
–
–
3 1
M
Mounting/
–
A
1
2
T
1
B
0
8
12
Agency
Approval
5
11
1
3
7
9
10
2
4
6
Terminal
Aux/Alarm
Switch
Max. Appl.
Rating
Series
Poles
Current Rating
Actuator
Color
Actuator
Circuit
Frequency
& Delay
Barriers
1 SERIES
7 CURRENT RATING (AMPERES)
A
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
285
290
295
410
512
415
517
420
522
527
430
435
440
445
450
0.850
0.900
0.950
1.000
1.250
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
455
5.500
613 13.000
460
465
470
475
480
485
490
495
610 10.000
710 10.500
611
711
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
6355 35.000
6405 40.000
6455 45.000
6505 50.000
2 ACTUATOR 1
Two Color Visi-Rocker
1
2
Single color
3
4
Push-To-Reset, Visi-Rocker
5
6
Push-To-Reset , Single color
7
8
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Vertical legend
Horizontal legend
11.000
11.500
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
612 12.000
712 12.500
Vertical legend
Horizontal legend
8 TERMINAL6
17
2
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
B
C
F
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Studs
Printed Circuit Board
Terminals
3 POLES2
1
38
4
One
2
Two
3
Three
58
6
G
4 CIRCUIT
B
Series Trip (Current)
H8
M8
P9
7
8
9
5 AUXILIARY/ALARM SWITCH3,4
0
1
2
3
w/o Aux Switch
7
S.P.S.T., 0.110 Q.C.
Q10 Push-In Stud
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
8
9
Screw 10-32 (Bus Type) and
30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
6 FREQUENCY & DELAY
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
52
54
56
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
Visi-Color11
Marking
Marking Color:
ON-OFF
Dual11
Single Color
Black
Visi-Rocker
White
Black
Red
Green
Blue
Yellow
Gray
Orange
B
D
G
J
1
2
3
4
5
6
7
8
White
n/a
White
White
Red
White
White
Green
Blue
L
N
Q
S
Black
Black
Yellow
Gray
Black
Orange
10 MOUNTING/BARRIERS12
BARRIERS
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
Notes:
1
2
FLAT ROCKER ACTUATOR
6-32 x 0.195 inches
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Aux. switch
and/or mixed poles, and have one rocker per breaker.
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half
shells. 30-50 amps are supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
VDE Certification available with single pole breakers only. UL489A Listing available with
one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9 G, H, M and Q.
Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps
with UL489A Listing, but is not recommended over 20 amps.
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock
Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and
Flat Washers. These breakers are only TUV or VDE Certified when the washers are
used.
1
A
2
no
yes
no
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
RECESSED OFF SIDE ROCKER ACTUATOR
6-32 x 0.195 inches
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
6-32 x 0.195 inches
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
3
B
yes
13
4
5
5
E
6
F
no
yes
no
6
7
8
yes
3
C
4
no
yes
no
D
ISO M3 x 5mm (multi-pole units only)
yes
9
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
Terminal Code Q not available with VDE certification.
Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O leg-
end.
10
11
11 MAXIMUM APPLICATION RATING
80 DC
M
12
13
Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator
codes 5 & 6.
Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are
available in ink stamping only.
12 AGENCY APPROVAL
T
J
UL489A Listed
UL489A Listed, TUV Certified
www.carlingtech.com
45
A-Series Handle – Circuit & Terminal Diagrams
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only.
46
www.carlingtech.com
A-Series Handle – Circuit & Terminal Diagrams
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Alarm Switch available with .110 x .020 QC & solder lug terminals only.
www.carlingtech.com
47
A-Series Handle – Form & Fit Drawings
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
For agency code P = .150 [3.81].
48
www.carlingtech.com
A-Series Handle – Front Panel Snap-In Mounting Style 5
Notes:
1
2
3
All dimensions are in inches [millimeters].
Recommended panel thickness: .040 [1.02] to .100 [2.54].
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
49
A-Series Handle – Front Panel Snap-In Mounting Style 7
Notes:
1
2
3
All dimensions are in inches [millimeters].
Recommended panel thickness: .040 [1.02] to .100 [2.54].
Tolerance ±.020 [.51] unless otherwise specified.
50
www.carlingtech.com
A-Series Sealed Toggle – Form & Fit Drawings
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
51
A-Series Rocker – Circuit & Terminal Diagrams
Notes:
1
2
3
4.
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Schematic shown represents current trip circuit.
Circuits shown for >30 amps / VDE.
52
www.carlingtech.com
A-Series Rocker – Form & Fit Drawings
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal
orientation on indicate OFF is opposite of indicate ON.
2
3
4
For pole orientation with horizontal legend, rotate front view clockwise 90°.
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
www.carlingtech.com
53
A-Series Rocker Snap-In Bracket – Form & Fit Drawings
Notes:
1
2
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal
For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation
on indicate "OFF" is opposite of indicate "ON"
3
4
5
Recommended panel thickness: .04 0 [1.02] to .100 [2.54]
All dimensions are in Inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
54
www.carlingtech.com
A-Series Flat Rocker – Form & Fit Drawings
Notes:
1
2
3
All dimensions are in inches [millimeters].
For pole orientation with horizontal legend, rotate front view clockwise 90°.
Tolerance ± 0.20 [.51] unless otherwise specified.
www.carlingtech.com
55
A-Series PC Terminal Diagrams
Notes:
1
2
3
Drawing illustrates A-Series with VDE certification.
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
56
www.carlingtech.com